<strike id="w6agu"><menu id="w6agu"></menu></strike>
  • <ul id="w6agu"><sup id="w6agu"></sup></ul>
  • <strike id="w6agu"><menu id="w6agu"></menu></strike>
    <ul id="w6agu"><sup id="w6agu"></sup></ul>
    當前位置: 選型首頁 >  沃康 >  儀器儀表 >系列介紹

    沃康  HSSC-A6   儀器儀表

    收錄型號: 0條(帶參數型號: 0 條)

    選型指南: 0 條 應用案例: 0

    安裝調試: 0 條 安裝調試: 0

    維護維修: 0 條 升級改造: 0

    收藏

    詳細介紹

    HSSC-A6series

    Specification

    Dimension

    50kPa~3MPa

    HSSC-A6_High temperature type

    50kPa~3MPa

    HSSC-A6_DIN connector type

    Digital pressure meter with large high-brightness LED(14.2mm) thanks to 2-wire transmission system.
    Constructed with stainless steel in view of environmental resistance.
    Safe and reliable construction with break-proof diaphragm.
    Safe and reliable construction with no sealed liquid.

    Measured mediumAlcohols, milk beverage, seasoning, pure water, chemical or other media that will not corrode SUS316L.
    Pressure typePositive, compound, and negative pressures can be measured.
    Pressure rangeCan be specified within the range of 50 kPa to 3 MPa (Calibration:25kPa~3MPa) of rated capacity.
    Specify more than 50% of rated capacity as the calibration range.
    Output type4~20mA (2 wire system)

    Specification 1 (Sensor assembly)

    Pressure Port Type/SizeISO Ferrule, VARIVENT®, ISO Cap nut, Screw mount, Other special orders
    Rated Capacity(R.C.)50, 100, 200, 300, 500, 1000kPa, 3MPa
    MaterialSensor: SUS316L
    Finish(Sensor Part)Electro-Chemical Buffing
    Safe Overload Rating400%R.C. (Rated capacity 3MPa: 150%R.C.)
    Destruction Point1000%R.C. (Rated capacity 3MPa: 300%R.C.)

    Specification 2 (Amplifier + Sensor assembly)

    Accuracy (*1)
    (Non Linearity, hysteresis and repeatability included.)
    ±0.3%R.C. (Rating: 300, 500, 1000kPa, 3MPa)
    ±0.35%R.C. (Rating: 50, 100, 200kPa)
    Compensated Temperature Range (Wetted part)High temperature: -5~150?C
    Safe Temperature Range (Wetted part)High temperature: -5~150?C
    Temperature Effect on Zero Balance±0.35%R.C./10?C (Rating: 300, 500, 1000kPa, 3MPa)
    ±0.3%R.C./10?C (Rating: 50, 100, 200kPa)
    Temperature Effect on Load±0.35%R.C./10?C (Rating: 300, 500, 1000kPa, 3MPa)
    ±0.3%R.C./10?C (Rating: 50, 100, 200kPa)
    Ambient Temperature and HumidityTemperature:0~50?C(No freezing), Humidity:0~90%RH(No condensation)
    MaterialSUS304(Case material), SUS304(Radiating fin)
    IP RatingEquivalent to IP65
    WeightApprox. 700g
    AccessoriesOperation manual (1 copy)(Specify English or Japanese.)
    Test report (1 copy)
    1 of hexagon nut(Cap nut only)
    • (*1) For the ferrule type, zero adjustment is to be made after the clamp is tightened.

    Model Selection

    Model Selection

    SelectionCheckModelSpecification
    1.ModelHSSCHigh temperature type: Temperature range of wetted parts -5~150?C Stainless steel case
    2.Display/Analog outputA63 ? digit Red LED Character height: Approx.14.2mm
    Display conversion rate: Fixed at approx. 2.5 times per second
    4~20mA(2 wire system) Response:50Hz Safe load resistance:400Ω or less
    3.Sensor ConnectionASSensor directly connected on bottom(Flangeless)
    4.Display angle
    Not availableDisplay angle: Front side, upward

    (3)Display angle: Front side, rightward

    (6)Display angle: Front side, downward

    (9)Display angle: Front side, leftward
    5.Display/Calibration--Example of calibration range

    PressurizationRated capacity
    At 1000kPa1000kPa
    (0~1000)kPa
    Specify the values and units of display/calibration ranges

    Negative pressureRated capacity
    At 100kPa-100kPa
    (0~-100)kPa
    In case of negative pressure, put the calibration range value in parentheses.(*2)

    Compound pressureRated capacity
    At 500kPa-100~500kPa
    (-100~500)kPa
    Put the output calibration range value and unit in parentheses.(*2)(*3)
    6.Rated Capacity(R.C.)
    00550kPa

    010100kPa

    020200kPa(*3)

    021200kPa(*3)
    (Specify this model at calibration for compound pressure if "focus on negative pressure" has been selected.)

    030300kPa(*3)

    031300kPa(*3)
    (Specify this model at calibration for compound pressure if "focus on negative pressure" has been selected.)

    050500kPa

    1001000kPa

    3003MPa[Make to order]
    7.Pressure Port Type/Size
    F1Ferrule 1.5S

    F2Ferrule 2S

    F3Ferrule 2.5S[Make to order]

    F4Ferrule 3S[Make to order]

    F6Ferrule 4S[Make to order]

    V50AVARIVENT® DN50[Make to order]

    V65AVARIVENT® DN65[Make to order]

    V80AVARIVENT® DN80[Make to order]

    V100AVARIVENT® DN100[Make to order]

    R1Cap nut 1.5S[Make to order] Hexagon nut included

    R2Cap nut 2S[Make to order] Hexagon nut included

    M0Screw mount type simple substance Dedicated O-ring included (×1)

    M1JIS20K50A With flange, Dedicated O-ring included (×1)

    M2JIS20K80A With flange, Dedicated O-ring included (×1)
    8.Pressure Port Material
    BlankSUS316L, Electro-Chemical Buffing(Ry0.7)
    ⑥Supports all rated capacities.
    ⑦Supports all pressure port type/size.

    HS1Hastelloy C276, Electro-Chemical Buffing(Ry0.7)
    ⑥Rated capacitor can be selected from among 300, 500 and 1000kPa.
    ⑦Pressure port type/size can be selected from among F1, F2, F3 and M0.

    J4LSUS329J4L, Buffing(#400)
    ⑥Rated capacitor can be selected from among 300, 500 and 1000kPa.
    ⑦Pressure port type/size can be selected from among F1, F2, F3 and M0.
    9.Limitation
    H400%R.C.

    Blank150%R.C.(3MPa only)
    10.Cable Connection
    DDIN connector type

    BlankPigtail 2m
    11.Power4DC24V(±10%)
    • (*2) Basically the calibration range is within the rated capacity, but other requirements are possible, as long as the range is 50% or more than the rating of the sensor used.
      Specify the display range between -200 and 200 digits for the 4 mA side and between 100 and 1999 digits for the 20 mA side.

    • (*3) In case of calibration for compound pressure, calibration is performed only for the positive pressure, and only measurement data are given for the negative pressure. In this case, acceptance criterion is within ±1%R.C. When focusing on the negative pressure, it is also possible to perform calibration for the negative pressure and to provide only measurement data (within ±1%R.C.) according to the request from the customer.
      Regarding calibration, specify 020, 030 (focus on positive pressure) or 021, 031 (focus on negative pressure) in ⑥ above when placing an order.


    主站蜘蛛池模板: 成人免费在线视频网站| 亚洲成人在线网| 国产成人精品无缓存在线播放| 欧洲成人在线视频| 欧美成人秋霞久久AA片| 国产成人精品免费视频大全麻豆| 国产成人爱片免费观看视频| 成人在线视频一区| 久久怡红院亚欧成人影院| 成人在线免费看| 亚洲国产成人综合| 国产日产成人免费视频在线观看| 99精品国产成人一区二区| 成人免费大片免费观看网站| 亚洲欧美成人中文日韩电影| 成人性生交大片免费看好| 亚洲国产成人久久综合一区| 成人免费无码大片a毛片| 欧美成人一区二区三区在线电影| 国产成人午夜片在线观看| 日本成人在线免费| 麻豆亚洲AV成人无码久久精品| 亚洲国产精品无码成人片久久| 国产成人无码a区在线观看视频| 欧美成人在线免费观看| 亚洲国产成人va在线观看网址 | 久久久久亚洲AV成人网| 成人午夜18免费看| 成人国产永久福利看片| 国内一级毛片成人七仙女| 国产成人午夜片在线观看| 日本成人在线免费| 欧美日韩国产成人精品| 亚洲色成人网一二三区| 国产成人精品午夜在线播放| 欧美日韩国产成人精品| 欧美日韩在线成人| 成人漫画免费动漫y| 成人毛片免费网站| 成人免费看www网址入口| 国产成人精品一区二区三区|